MSW Feeder

Density (kg/m3): 815 - 826
Gravity (oAPI): 39 - 42

▸ Federated (FD)

▸ Peace (MPR)

▸ Pembina (P)

Light Sweet

Density (kg/m3): 818 - 825
Gravity (oAPI): 40 - 42

▸ Mixed Sweet Blend (MSW)

▸ Rainbow (RA)

Medium Sour

Density (kg/m3): 839 - 874
Gravity (oAPI): 30 - 37

▸ Hardisty Light (MBL)

▸ Medium Gibson Sour (MGS)

▸ Midale (MSM)

▸ Peace Pipe Sour (SPR)

Heavy Sour - Synbit

Density (kg/m3): 930 - 936
Gravity (oAPI): 19 - 21

▸ Long Lake Heavy (PSH)

▸ Statoil Cheecham Synbit (SCS)

▸ Surmont Heavy Blend (SHB)

Heavy Sour - Dilsynbit

Density (kg/m3): 935 - 936
Gravity (oAPI): 19 - 20

▸ Albian Heavy Synthetic (AHS)

Heavy Low Resid

Density (kg/m3): 937 - 938
Gravity (oAPI): 19 - 20

▸ Suncor Synthetic H (OSH)






Reports for Shell Synthetic Light

Batch: SSX-621 - Edmonton

Date: Apr 1, 2014
BTEX was slightly reduced in the April sample of Shell Synthetic Light.
View sample data.


Batch: SSX-892 - Edmonton

Date: Feb 3, 2014
Marginally elevated butanes were observed in the February sample of Shell Synthetic Light. Typical distillation results are included.
View sample data.


Batch: SSX-624 - Edmonton

Date: Dec 2, 2013
Apart from a marginally elevated MCR, Shell Synthetic Light was consistent with historical averages for the month of December.
View sample data.


Batch: SSX-611 - Edmonton

Date: Oct 16, 2013
Density was slightly elevated for the October sample of Shell Synthetic Light.
View sample data.


Batch: SSX-609 - Edmonton

Date: Aug 3, 2013
Density and pentanes were slightly increased for the August sample of Shell Synthetic Light. BTEX and C7 x C10 content were slightly reduced. Simulated distillation results indicate a shift from the naphtha fraction to the distillate fraction.
View sample data.


Batch: SSX-649 - Edmonton

Date: Jun 17, 2013
Density, sulphur, and butanes were slightly elevated in the June sample of Shell Synthetic Light. A reduction in BTEX content was also observed.
View sample data.


Batch: SSX-645 - Edmonton

Date: Apr 20, 2013
Marginally elevated hexanes and reduced butanes were detected in the April sample of Shell Synthetic Light.
View sample data.


Batch: SSX-673 - Edmonton

Date: Feb 6, 2013
Marginally increased pentanes as well as reduced heptanes and octanes were observed in the February sample of Shell Synthetic Light.
View sample data.


Batch: SSX-904 - Edmonton

Date: Dec 1, 2012
Elevated sulphur and pentanes as well as reduced C7 x C10 concentrations were observed in the December sample of Shell Synthetic Light.
View sample data.


Batch: SSX-605 - Edmonton

Date: Oct 6, 2012
While the pentanes content is high the remaining light ends displayed slightly reduced volumes. This is reflected in the simulated distillation by a reduction in the naphtha and distillate fractions. Slightly decreased BTEX was also experienced for this October sample.
View sample data.


Batch: SSX-882 - Edmonton

Date: Aug 1, 2012
Marginally reduced C6 x C9 content and elevated pentanes resulted in a slightly elevated density for the August sample of Shell Synthetic Light.
View sample data.


Batch: SSX-609 - Edmonton

Date: Jun 5, 2012
Apart from slightly increased butanes and sulphur, the results for the June sample of Shell Light Synthetic were consistent with historical data.
View sample data.


Batch: SSX-603 - Edmonton

Date: Apr 6, 2012
Other than a marginally elevated pentanes content, the April sample of Shell Synthetic Light was normal and average in all aspects. The minimal MCR and absence of metals confirms the bottomless nature of this synthetic crude oil. The simulated distillation confirms that the composition of the April sample was normal in all regards.
View sample data.


Batch: SSX-611 - Edmonton

Date: Feb 9, 2012
The February sample of SSX appeared to be relatively consistent with historical quality characteristics for the stream.
View sample data.


Batch: SSX-840 - Edmonton

Date: Dec 26, 2011
Other than an unusually high pentanes content (5.27 vol% versus an approximately 3.0 vol% average in recent samples), the December sample of SSX was reasonably typical of the historical characteristics.
View sample data.


Batch: SSX-609 - Edmonton

Date: Oct 21, 2011
A marginal increase in pentanes and lower than average C6s x C9s and BTEX were noted for the October sample of Shell Synthetic Light. No metals were detected.
View sample data.


Batch: SSX-807 - Edmonton

Date: Jun 26, 2011
Increases in density, sulphur, and pentanes, along with decreases in BTEX and C7s x C9s, were observed for the June sample of SSX. No metals were detected.
View sample data.


Batch: SSX-797 - Edmonton

Date: May 23, 2011
The May sample of Shell Synthetic Light had elevated sulphur and MCR as well as above average C4s x C5s and C9s x C10s. The simulated distillation results reflected an increase in the naphtha component. No nickel was detected.
View sample data.


Batch: SSX-793 - Edmonton

Date: Apr 21, 2011
Slight decreases in BTEX and C7s x C8s along with above average C4s x C5s were observed for this month's sample of SSX. No metals were detected.
View sample data.


Batch: SSX-779 - Edmonton

Date: Mar 27, 2011
The March sample of SSX had above average C4s x C5s, along with slight decreases in BTEX and C7s x C8s. No metals were detected.
View sample data.


Batch: SSX-773 - Edmonton

Date: Feb 21, 2011
Decreases in BTEX and C7s x C8s, along with increased C4s x C5s and C10s, were observed for the February sample of SSX. No metals were detected. The simulated distillation results reflected an increase in distillate and decrease in the size of the gas oil component.
View sample data.


Batch: SSX-761 - Edmonton

Date: Jan 29, 2011
Slight increases in C4s x C5s and decreases in BTEX and C7s x C9s were observed for the January sample of SSX. No MCR, metals, or olefins were detected.
View sample data.


Batch: SSX-759 - Edmonton

Date: Dec 21, 2010
Decreased BTEX and C6s x C9s and increased C4s x C5s were detected for the December sample of Shell Synthetic Light. No metals were detected.
View sample data.


Batch: SSX-752 - Edmonton

Date: Nov 23, 2010
A marginal increase in MCR, along with decreased toluene and C5s x C8s, were observed for this month's sample of SSX. No metals or MCR were detected. The sample's simulated distillation results indicated a decrease in naphtha, which is consistent with the observed shifts in light ends.
View sample data.


Batch: SSX-743 - Edmonton

Date: Oct 31, 2010
Slightly decreased C4s x C5s and C7s and a marginally increased density were observed for the October sample of SSX. No metals were detected.
View sample data.


Batch: SSX-737 - Edmonton

Date: Sep 23, 2010
Slight increases in benzene and sulphur were detected for this month's sample of SSX. No metals or MCR were detected. The sample's simulated distillation results indicated an increase in distillate and decrease in the gas oil component.
View sample data.


Batch: SSX-732 - Edmonton

Date: Aug 21, 2010
Slight increases in C9s x C10s and decreases in C7s were present in this month's sample of SSX. Density was higher than typically observed, but no MCR and no metals were detected.
View sample data.


Batch: SSX-729 - Edmonton

Date: Jul 26, 2010
The July sample of SSX had increased density, sulphur, MCR, and C9s x C10s. Slight decreases in C4s x C6s were also observed. No metals were detected.
View sample data.


Batch: SSX-720 - Edmonton

Date: Jun 26, 2010
The June sample of SSX had slightly decreased C6s but increased C9s x C10. The sample's density was higher than average (871 versus 857 kg/m³ historical average). No metals were detected.
View sample data.


Batch: SSX-715 - Edmonton

Date: May 31, 2010
Apart from a slight increase in benzene, the results for the May sample of SSX were in line with average values. No metals were detected. The simulated distillation results reflected an increase in the gas oil component along with a similar decrease in distillate.
View sample data.


Batch: SSX-713 - Edmonton

Date: Apr 9, 2010
Apart from a slight increase in benzene, the results for the April sample of SSX were in line with average values. No metals were detected.
View sample data.


Batch: SSX-710 - Edmonton

Date: Mar 19, 2010
Slight increases in sulphur and density were observed for the March sample of SSX. No nickel was detected.
View sample data.


Batch: SSX-705 - Edmonton

Date: Feb 12, 2010
Increased C4s x C5s and decreased C7s x C9s and BTEX were observed for the February sample of Shell Synthetic Light. No metals were detected. The sample's simulated distillation distribution indicated a slight decrease in the naphtha component.
View sample data.


Batch: SSX-698 - Edmonton

Date: Jan 23, 2010
The January sample of Shell Synthetic Light had increased C4s x C5s and decreased C7s x C9s and BTEX. No metals were detected.
View sample data.