Distillation - Synbit Blend


Most Recent Sample: (SYB-935) Jan 04, 2018

Mass % Recovered

Temperature
( oC )

Temperature
( oF )

% Difference
from Normalised

IBP

-0.5

31.1

-

5

99.2

210.6

-29.7%

10

174.9

346.8

-6.21%

20

258.4

497.1

3.3%

30

311.4

592.5

2.62%

40

355.5

671.9

0.48%

50

400.0

752.0

-1.13%

60

448.1

838.6

-2.34%

70

520.8

969.4

-0.15%

80

630.4

1,166.7

3.71%

90

-

-

-

95

-

-

-

99

-

-

-


This data was obtained through ASTM D7900/D7169 Merged Simulated Distillation.


Cut Analyser

Product

Temperature   oC oF

Fraction (%)

Cut 1

Residual

Add Product
  
Remove Product
  
Compute

Interpolation calculator for recent sample yield

Calculate either the expected mass % recovery at a given temperature, or the expected temperature necessary to achieve a particuar mass % recovery by entering your number into the form and pressing the appropriate button.


  oC oF



Interpolation calculator for historical average yield
  oC oF