Distillation - Premium Conventional Heavy



Mass % Recovered

Temperature
( oC )

Standard Deviation
( oC )

Temperature
( oF )

Standard Deviation
( oF )

% Difference
from Normalised

IBP

20.1

19.6

68.2

35.3

-

5

-

60.6

-

109.1

-

10

116.7

25.9

242.1

46.6

18.59%

20

242.3

19.7

468.1

35.5

-0.77%

30

328.1

16.5

622.7

29.7

-4.84%

40

396.6

16.6

745.8

29.9

-5.15%

50

458.6

16.6

857.5

29.9

-4.53%

60

523.3

17.5

974.0

31.5

-2.87%

70

597.7

20.7

1,107.8

37.3

-0.3%

80

683.5

23.7

1,262.4

42.7

-14.93%

90

708.5

3.3

1,307.3

5.9

-29.2%

95

-

-

-

-

-

99

-

-

-

-

-


This data was obtained through ASTM D7900/D7169 Merged Simulated Distillation.


Cut Analyser

Product

Temperature   oC oF

Fraction (%)

Cut 1

Residual

Add Product
  
Remove Product
  
Compute

Interpolation calculator for historical average yield
  oC oF