Distillation - Cold Lake



Mass % Recovered

Temperature
( oC )

Temperature
( oF )

% Difference
from Normalised

IBP

34.1

93.4

-

5

38.0

100.4

-11.56%

10

90.4

194.7

-22.03%

20

246.8

476.2

4.55%

30

331.4

628.5

1.36%

40

401.4

754.5

-0.37%

50

465.6

870.1

-1.33%

60

537.7

999.9

-0.26%

70

617.9

1,144.2

1.22%

80

698.7

1,289.7

-0.65%

90

-

-

-

95

-

-

-

99

-

-

-


This data was obtained through ASTM D7169 High Temperature Simulated Distillation.


Cut Analyser

Product

Temperature   oC oF

Fraction (%)

Cut 1

Residual

Add Product
  
Remove Product
  
Compute

Interpolation calculator for recent sample yield

Calculate either the expected mass % recovery at a given temperature, or the expected temperature necessary to achieve a particuar mass % recovery by entering your number into the form and pressing the appropriate button.


  oC oF



Interpolation calculator for historical average yield
  oC oF